CB

Part verified by Christopher Bacon — co-founder of Orthoscan, Inc. and mini C-arm industry expert

What Is the OEC 6800 Isolation Transformer (00-900971-01)?

Product: OEC 6800 Isolation Transformer

Part Number: 00-900971-01

The OEC 6800 Isolation Transformer (00-900971-01) is the mains isolation transformer for the OEC 6800 mini C-arm. This component electrically isolates the system from the AC power supply, protecting patients and clinical staff from leakage current — a critical patient safety requirement for medical electrical equipment used in operating room and procedure room environments. Failure or degradation of the isolation transformer can result in the unit failing electrical safety testing, tripping ground fault protection, or failing to power on reliably. Replacement must be performed by a certified field service engineer. Compatible with the OEC 6800 only — not the OEC 6600, Elite Miniview, or MiniView MAX. Call (800) 643-2998 with your serial number and fault description before ordering.

Compatible Systems

This isolation transformer (00-900971-01) is specific to the OEC 6800 only. The OEC 6600, Elite Miniview, and MiniView MAX use different transformer configurations. Call (800) 643-2998 with your serial number and a description of the fault before ordering to ensure correct part identification.

Why Source This Part From Minicarm.com?

✓ Mini C-Arm Parts SpecialistsMinicarm.com stocks parts for OEC, Orthoscan, and Hologic mini C-arms. One source for everything your system needs, backed by over 65 years of imaging experience.
✓ 30-Day Warranty on Every PartEvery part ships with a 30-day industry-standard warranty. If there's an issue, we make it right — no runaround.
✓ Same-Day Shipping AvailableCall before 5PM EST and we'll do our best to get your part out the same day.
✓ 4.9 Stars on Google (60 Reviews)Medical imaging professionals across the country trust Minicarm.com for parts, service, and support.

Need Installation Help?

Isolation transformer replacement involves high-voltage internal wiring and must be performed by a certified field service engineer. Following installation, electrical safety verification testing is required before returning the unit to clinical use. Our technicians are available nationwide for on-site replacement and post-installation safety testing. Learn more about our service options or call (800) 643-2998 to schedule.

Order Information📦 All parts are sold based on exchange.🔄 Return Policy: All sales are final. Parts are non-returnable.🛡️ Warranty: 30-Day Industry-Standard WarrantyQuestions? Contact us at minicarm.com/contact-us or call (800) 643-2998.

Frequently Asked Questions

What does the isolation transformer do on the OEC 6800?+
The isolation transformer electrically separates the OEC 6800 from the building's AC mains power supply. This isolation prevents dangerous leakage current from reaching the patient or clinical staff during a procedure, which is a fundamental patient safety requirement for medical electrical equipment. Medical-grade isolation transformers are designed and tested to meet IEC 60601 standards for electrical safety in healthcare settings. A failed or degraded isolation transformer can cause the unit to fail annual electrical safety inspections or trip ground fault protection circuits.
What symptoms indicate the isolation transformer needs to be replaced?+
Common indicators include the unit failing its annual electrical safety inspection (elevated leakage current readings), the system tripping ground fault circuit interrupters (GFCIs) at the wall outlet, intermittent power loss during operation, or a burning smell from the unit. If your facility's biomedical engineering team has flagged an electrical safety failure, the isolation transformer is one of the first components to evaluate. Call (800) 643-2998 to discuss your fault before ordering.
Can Minicarm.com install this part for me?+
Yes. Our certified field service engineers are available nationwide for on-site installation and repair. Following isolation transformer replacement, we perform electrical safety verification testing before returning the unit to service. Call (800) 643-2998 or visit minicarm.com/service to schedule.
What does sold on exchange mean?+
Exchange means you return your defective core unit when you receive the replacement. This helps keep refurbished parts available and costs reasonable. Our team will provide return instructions with your order.
How quickly can I get this part shipped?+
Same-day shipping is available on in-stock parts when ordered before 5PM EST. Call (800) 643-2998 to confirm availability and arrange shipping.

Need More OEC Parts?

Browse our full inventory of OEC components — transformers, boards, casters, and more.

Browse OEC Parts

Request a Quote

Name(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form

Schedule An Engineer

Name(Required)
Address(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form