Description

CB

Part verified by Christopher Bacon — co-founder of Orthoscan, Inc. and mini C-arm industry expert

What Is the Hologic Fluoroscan Premier Image Intensifier (111035)?

Product: Hologic Fluoroscan Premier Image Intensifier

Part Number: 111035

The Hologic Fluoroscan Premier Image Intensifier (111035) is the core imaging component of the Hologic Fluoroscan Premier mini C-arm. The image intensifier (II) captures X-ray photons exiting the patient, converts them to light via a cesium iodide input phosphor, amplifies that signal electronically, and outputs a visible image at the output phosphor for capture by the camera assembly. On the Fluoroscan Premier, the II is a dual 6″/4″ cesium iodide design offering operator-selectable field of view for both large-area imaging such as knees and shoulders and fine-detail extremity imaging such as toes and fingers. The image intensifier is the most critical component in the imaging chain for a conventional II-based mini C-arm — degradation of the II directly impacts image brightness, resolution, contrast, and noise. Common failure presentations include progressive loss of image brightness, increased quantum mottle (grainy appearance), vignetting or dark areas within the field of view, and geometric distortion. II replacement is a major service event that requires post-installation imaging performance verification by a qualified service engineer. Compatible with the Hologic Fluoroscan Premier only. Call (800) 643-2998 with your serial number to confirm fit before ordering.

Compatible Systems

Part 111035 is specific to the Hologic Fluoroscan Premier only. The InSight 1 and InSight 2 use different image intensifier assemblies with their own part numbers. The InSight FD and InSight FD Flex use a flat panel detector rather than an image intensifier entirely. Image intensifier replacement is a major service procedure — post-installation imaging performance verification is required before returning the unit to clinical use. Call (800) 643-2998 with your serial number to confirm fit before ordering.

Why Source This Part From Minicarm.com?

✓ Mini C-Arm Parts SpecialistsMinicarm.com stocks parts for Hologic, Orthoscan, and OEC mini C-arms. One source for everything your system needs, backed by over 65 years of imaging experience.
✓ 30-Day Warranty on Every PartEvery part ships with a 30-day industry-standard warranty. If there's an issue, we make it right — no runaround.
✓ Same-Day Shipping AvailableCall before 5PM EST and we'll do our best to get your part out the same day.
✓ 4.9 Stars on Google (60 Reviews)Medical imaging professionals across the country trust Minicarm.com for parts, service, and support.

Need Installation Help?

Image intensifier replacement is a major service procedure involving the core imaging assembly of the C-arm and must be followed by post-installation imaging performance verification before the unit is returned to clinical use. Our certified field service engineers are available nationwide for on-site installation, alignment, and verification. Learn more about our service options or call (800) 643-2998 to schedule.

Order Information📦 All parts are sold based on exchange.🔄 Return Policy: All sales are final. Parts are non-returnable.🛡️ Warranty: 30-Day Industry-Standard WarrantyQuestions? Contact us at minicarm.com/contact-us or call (800) 643-2998.

Frequently Asked Questions

What are the signs that the image intensifier on a Fluoroscan Premier is failing?+
The most common signs of image intensifier degradation include progressive loss of image brightness that requires increasing dose to compensate, increased image noise or graininess (quantum mottle), vignetting or dark patches within the field of view, loss of image sharpness or resolution at the edges of the field, and geometric distortion. These changes typically develop gradually over years of clinical use and may not be immediately obvious until a comparison is made against a new or recently replaced II.
What field of view options does the Fluoroscan Premier image intensifier offer?+
The Fluoroscan Premier image intensifier is a dual 6″/4″ cesium iodide design. The 6″ field of view is used for larger structures such as knees, shoulders, and forearms, while the 4″ field provides a magnified view for fine-detail imaging of smaller structures such as toes, fingers, and small joint anatomy. Field of view is operator-selectable from the system's control interface.
Can Minicarm.com install this part for me?+
Yes. Our certified field service engineers are available nationwide for on-site installation, post-installation imaging verification, and performance testing. Call (800) 643-2998 or visit minicarm.com/service to schedule.
What does sold on exchange mean?+
Exchange means you return your defective core unit when you receive the replacement. This helps keep refurbished parts available and costs reasonable. Our team will provide return instructions with your order.
How quickly can I get this part shipped?+
Same-day shipping is available on in-stock parts when ordered before 5PM EST. Call (800) 643-2998 to confirm availability and arrange shipping.

Need More Hologic Parts?

Browse our full inventory of Hologic parts — computers, cables, assemblies, and more.

Browse Hologic Parts

Request a Quote

Name(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form

Schedule An Engineer

Name(Required)
Address(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form