Hologic InSight FD “C” with Carriage Assy

Hologic InSight FD “C” with Carriage Assy

Hologic InSight FD “C” with Carriage Assy

Part Number: ASY-05408Compatible: Hologic InSight FD, InSight FD FlexCondition: Refurbished
🚚 Same-Day Shipping🛡️ 30-Day Warranty📞 (800) 643-2998🔧 Nationwide Service

Call (800) 643-2998 or click Request A Quote for pricing. All parts sold on exchange — all sales final.

SKU: ASY-05408 Category:

Description

CB

Part verified by Christopher Bacon — co-founder of Orthoscan, Inc. and mini C-arm industry expert

What Is the Hologic InSight FD C-Arm with Carriage Assembly (ASY-05408)?

Product: Hologic InSight FD C-Arm with Carriage Assembly

Part Number: ASY-05408

The Hologic InSight FD C-Arm with Carriage Assembly (ASY-05408) is the complete C-shaped arm structure and its carriage mechanism for the Hologic InSight FD and InSight FD Flex mini C-arms. This assembly is the core mechanical framework of the imaging head — the C-shaped structure holds the X-ray tube on one end and the flat panel detector on the other, while the carriage allows the C-arm to slide and rotate for patient positioning and oblique imaging angles. Common reasons for replacement include physical damage to the C-arm structure from a drop or collision, a carriage mechanism that has lost smooth travel or become locked in position, worn or cracked carriage components that compromise positioning precision, and full mechanical refurbishment before resale or redeployment. This is one of the largest and most significant assemblies on the InSight FD and requires a certified field service engineer for replacement. Compatible with the Hologic InSight FD and InSight FD Flex only — not the InSight 2, InSight 1, or Fluoroscan Premier Encore. Call (800) 643-2998 with your serial number to confirm fit before ordering.

Compatible Systems

Part ASY-05408 is specific to the Hologic InSight FD and InSight FD Flex only. The InSight 2, InSight 1, and Fluoroscan Premier Encore use different C-arm and carriage configurations. This is a major structural assembly — call (800) 643-2998 with your serial number to confirm fit and discuss installation before ordering.

Why Source This Part From Minicarm.com?

✓ Mini C-Arm Parts SpecialistsMinicarm.com stocks parts for Hologic, Orthoscan, and OEC mini C-arms. One source for everything your system needs, backed by over 65 years of imaging experience.
✓ 30-Day Warranty on Every PartEvery part ships with a 30-day industry-standard warranty. If there's an issue, we make it right — no runaround.
✓ Same-Day Shipping AvailableCall before 5PM EST and we'll do our best to get your part out the same day.
✓ 4.9 Stars on Google (60 Reviews)Medical imaging professionals across the country trust Minicarm.com for parts, service, and support.

Need Installation Help?

C-arm and carriage assembly replacement is a complex mechanical procedure requiring disconnection of the umbilical cable, removal of all tube head and detector components, and precise reassembly. This work must be performed by a certified field service engineer. Our technicians are available nationwide for on-site replacement. Learn more about our service options or call (800) 643-2998 to schedule.

Order Information📦 All parts are sold based on exchange.🔄 Return Policy: All sales are final. Parts are non-returnable.🛡️ Warranty: 30-Day Industry-Standard WarrantyQuestions? Contact us at minicarm.com/contact-us or call (800) 643-2998.

Frequently Asked Questions

What are the most common reasons to replace the C-arm and carriage assembly on the InSight FD?+
The most common reasons include physical damage to the C-arm structure from a drop or collision that bends or cracks the arm, a carriage mechanism that no longer slides or rotates smoothly due to worn bearings or damaged rails, a carriage that locks or binds during positioning, and full mechanical refurbishment before resale or redeployment. Because the C-arm carries the umbilical cable and all imaging components, structural damage that affects positioning accuracy or cable routing can directly impact image quality and clinical workflow.
What does the carriage assembly do on the InSight FD?+
The carriage is the mounting and travel mechanism that connects the C-arm to the system column and allows the arm to slide forward and backward as well as rotate for oblique imaging angles. Smooth, precise carriage travel is essential for accurate patient positioning — a worn or damaged carriage can make it difficult to center the anatomy of interest in the imaging field and may require excessive force to reposition, risking further damage to the system or injury to the patient.
Can Minicarm.com install this part for me?+
Yes. Our certified field service engineers are available nationwide for on-site installation and repair. Call (800) 643-2998 or visit minicarm.com/service to schedule.
What does sold on exchange mean?+
Exchange means you return your defective core unit when you receive the replacement. This helps keep refurbished parts available and costs reasonable. Our team will provide return instructions with your order.
How quickly can I get this part shipped?+
Same-day shipping is available on in-stock parts when ordered before 5PM EST. Call (800) 643-2998 to confirm availability and arrange shipping.

Need More Hologic Parts?

Browse our full inventory of Hologic parts — computers, cables, assemblies, and more.

Browse Hologic Parts

Request a Quote

Name(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form

Schedule An Engineer

Name(Required)
Address(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form