What Is the Hologic InSight FD Flat Panel Detector (ASY-05713 / ASY-11315)?
Product: Hologic InSight FD Flat Panel Detector Assembly
Part Number: ASY-05713
Alternate Part Number: ASY-11315
The Hologic InSight FD Flat Panel Detector (ASY-05713 / ASY-11315) is the digital flat-panel imaging detector housed in the C-arm head of the Hologic InSight FD Mini C-Arm. It is the core image-capturing component — replacing the image intensifier technology used in older systems like the InSight 1 and InSight 2. The flat-panel detector captures the x-ray beam that passes through the patient, converts it to a digital signal, and transmits the image data to the image processor board for display and storage. A failing detector typically causes a blank or severely degraded image despite the tube head firing normally, persistent fixed-pattern noise or dead pixel areas on the fluoroscopic image, or complete loss of image output with no x-ray error code. This is a high-value assembly — proper diagnosis before ordering is strongly recommended.
Compatible Systems
• Hologic InSight FD
Important: Flat panel detector failure symptoms closely mimic image processor board failure. Before ordering this high-value assembly, call
(800) 643-2998 — our technicians can help you isolate whether the detector, the image processor board (
CMP-00973), or another component is the root cause.
Why Source This Part From Minicarm.com?
✓ Founded by the Founder of OrthoscanChristopher Bacon co-founded Orthoscan, Inc. and designed the x-ray tube head used in the first five generations of their machines. You're buying from the experts.
✓ 30-Day Warranty on Every PartEvery part ships with a 30-day, industry-standard warranty. If there's an issue, we make it right — no runaround.
✓ Same-Day Shipping AvailableCall before 5PM EST and we'll do our best to get your part out the same day.
✓ 4.9 Stars on Google (60 Reviews)Medical imaging professionals across the country trust Minicarm.com for parts, service, and support.
Need Installation Help?
Flat panel detector replacement requires careful calibration after installation to ensure proper image quality. Our certified field service engineers are available nationwide and experienced with InSight FD detector replacement. Learn more about our service options or call (800) 643-2998 to schedule.
Order Information📦 All parts are sold based on exchange.🔄 Return Policy: All sales are final. Parts are non-returnable.🛡️ Warranty: 30-Day Industry-Standard Warranty❓ Questions? Contact us at minicarm.com/contact-us or call (800) 643-2998. Frequently Asked Questions
What does the InSight FD flat panel detector do?+
The flat panel detector is the image sensor opposite the x-ray tube. When x-rays pass through the patient and strike the detector, it converts the radiation pattern into a digital signal that is transmitted to the image processor board and rendered as a fluoroscopic image on the monitor. It replaces the bulkier image intensifier technology used in older Mini C-Arm systems like the InSight 2, delivering higher resolution and distortion-free images in a more compact form factor.
How do I know if it's the detector or the image processor board that's failing?+
Both can produce similar symptoms — blank image, no fluoroscopic output, or heavy noise. However, detector failures more often present with fixed-pattern artifacts, dead pixel regions, or partial image loss, while image processor board failures tend to cause total image loss. A skilled technician can distinguish them through specific diagnostic steps. Call us at (800) 643-2998 before ordering this high-value assembly — our team can walk you through the diagnostic process.
Is ASY-05713 the same as ASY-11315?+
ASY-05713 and ASY-11315 are the part numbers listed for the InSight FD flat panel detector. Call us at (800) 643-2998 with your serial number to confirm which designation applies to your specific unit before ordering.
What does sold on exchange mean?+
Exchange means you return your defective core unit when you receive the replacement. This helps keep costs down and ensures defective units are properly refurbished. Our team will provide return instructions with your order.
Does detector replacement require a service engineer?+
Yes. Flat panel detector replacement requires post-installation calibration to ensure accurate image geometry and quality. We strongly recommend using a certified FSE. Our nationwide team is available — call
(800) 643-2998 or visit our
service page to schedule.