Orthoscan FD Pulse Video Processing Board *XP

Orthoscan FD Pulse Video Processing Board *XP

Orthoscan FD Pulse Video Processing Board *XP

Part Number: 915-0013-04Compatible: Orthoscan FD Pulse (Windows XP)Condition: Refurbished
🚚 Same-Day Shipping🛡️ 30-Day Warranty📞 (800) 643-2998🔧 Nationwide Service

Call (800) 643-2998 or click Request A Quote for pricing. All parts sold on exchange — all sales final.

SKU: 915-0013-04 Category:

Description

CB

Part verified by Christopher Bacon — co-founder of Orthoscan, Inc. and mini C-arm industry expert

What Is the Orthoscan FD Pulse Video Processing Board — Windows XP (915-0013-04)?

Product: Orthoscan FD Pulse Video Processing Board — Windows XP

Part Number: 915-0013-04

The Orthoscan FD Pulse Video Processing Board (915-0013-04) is the Windows XP video processing and computer assembly for the Orthoscan FD Pulse mini C-arm. This is a complete assembly that includes the hard drive, computer, and motherboard — it is the core computing and image processing platform for the FD Pulse system running Windows XP. The video processing board handles flat detector image acquisition, processing, and output to the display system, and also runs the system software and user interface. This is the Windows XP version — confirm your FD Pulse is running Windows XP before ordering. Failure of this assembly typically presents as a complete failure to boot, a completely absent or corrupted image, system software errors, or hard drive failure. Because this is a complete computer assembly running the system operating environment, replacement requires post-installation software configuration and system verification by a qualified service engineer before the unit is returned to clinical use. Compatible with the Orthoscan FD Pulse (Windows XP) only. Call (800) 643-2998 with your serial number to confirm fit and software version before ordering.

What's Included

This assembly includes the hard drive, computer, and motherboard — a complete video processing and computer replacement for the Orthoscan FD Pulse (Windows XP).

Compatible Systems

Part 915-0013-04 is the Windows XP video processing board for the Orthoscan FD Pulse only. FD Pulse units running Windows 7 require a different board — see 915-0013-06. The Orthoscan FD, FD-OR, and MDI running Windows XP use a different assembly — see 915-0013-03. Do not substitute across models or OS versions. Always confirm your unit's exact model, serial number, and operating system before ordering. Call (800) 643-2998 and our team will confirm the correct board for your system.

Why Source This Part From Minicarm.com?

✓ Founded by the Founder of OrthoscanChristopher Bacon co-founded Orthoscan, Inc. and designed the x-ray tube head used in the first five generations of their machines. You're buying from the experts.
✓ 30-Day Warranty on Every PartEvery part ships with a 30-day, industry-standard warranty. If there's an issue, we make it right — no runaround.
✓ Same-Day Shipping AvailableCall before 5PM EST and we'll do our best to get your part out the same day.
✓ 4.9 Stars on Google (60 Reviews)Medical imaging professionals across the country trust Minicarm.com for parts, service, and support.

Need Installation Help?

Video processing board replacement on the FD Pulse involves replacing the complete computer assembly and requires post-installation software configuration and system verification before the unit is returned to clinical use. Our certified field service engineers are available nationwide for on-site installation and system verification. Learn more about our service options or call (800) 643-2998 to schedule.

Order Information📦 All parts are sold based on exchange.🔄 Return Policy: All sales are final. Parts are non-returnable.🛡️ Warranty: 30-Day Industry-Standard WarrantyQuestions? Contact us at minicarm.com/contact-us or call (800) 643-2998.

Frequently Asked Questions

What does this assembly include and what does it do?+
This is a complete video processing and computer assembly that includes the hard drive, computer, and motherboard. It handles flat detector image acquisition, image processing, and output to the display system, and also runs the system software and user interface for the Orthoscan FD Pulse. It is the core computing platform for the system and controls both image processing and system operation.
What is the difference between 915-0013-04 (XP) and 915-0013-06 (Win7)?+
Both are FD Pulse video processing board assemblies but for different operating system versions. Part 915-0013-04 is for FD Pulse units running Windows XP. Part 915-0013-06 is for FD Pulse units running Windows 7 and includes a 24" monitor. Installing the wrong OS version will result in a non-functional system. Always confirm your unit's operating system before ordering — call (800) 643-2998 and our team will confirm the correct board.
Can Minicarm.com install this part for me?+
Yes. Our certified field service engineers are available nationwide for on-site installation and system verification. Call (800) 643-2998 or visit minicarm.com/service to schedule.
What does sold on exchange mean?+
Exchange means you return your defective core unit when you receive the replacement. This helps keep refurbished parts available and costs reasonable. Our team will provide return instructions with your order.
How quickly can I get this part shipped?+
Same-day shipping is available on in-stock parts when ordered before 5PM EST. Call (800) 643-2998 to confirm availability and arrange shipping.

Need More Orthoscan Parts?

Browse our full inventory of Orthoscan parts — detectors, monitors, hard drives, power supplies, and more.

Browse Orthoscan Parts

Request a Quote

Name(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form

Schedule An Engineer

Name(Required)
Address(Required)
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form